Wastewater treatment plant sampling and water analysis
An analysis of the treated water shows whether your wastewater treatment plant (WWTP) meets the limits set in its discharge permit (povolenie na vypúšťanie). We take the sample correctly, deliver it to an accredited laboratory and record the result in the operating log (prevádzkový denník). If the plant does not meet the limits, we find out why and put it right.
On this page
How often
The scope and frequency of the analyses are set by your permit from the district office (okresný úrad). For sources of up to 50 population equivalent (PE, Slovak EO), Government Regulation No. 269/2010 Coll. specifies:
| Where you discharge | Number of samples |
|---|---|
| into surface waters (stream, river, channel) | 1 sample a year |
| into groundwater (infiltration) | 2 samples a year |
For plants up to 50 PE, a qualified spot sample is sufficient. Samples for compliance checks are taken by a certified inspection technician (revízny technik). There must be a point at the WWTP outlet where a sample can be taken.
What the analysis looks at
- BOD5 (Slovak BSK5): biochemical oxygen demand over five days, i.e. how much of the pollution that bacteria can break down is still left in the water
- CODCr (Slovak CHSKCr): chemical oxygen demand, a measure of the total organic pollution
- TSS (Slovak NL): total suspended solids, i.e. sludge and solid particles in the effluent
- NH4-N (Slovak N-NH4): ammonium nitrogen, which shows whether nitrification is taking place in the plant
- Ntot (Slovak Ncelk): total nitrogen, which also shows how well nitrogen is removed by denitrification
- Ptot (Slovak Pcelk): total phosphorus
- E. coli and enterococci: indicators of faecal contamination, monitored in category +D
Which parameters are monitored at your plant depends on the plant category set by the authority.
Limits by WWTP category
Maximum values in a qualified spot sample for small WWTPs up to 50 PE under Annex 6 of Government Regulation 269/2010.
Discharge into surface waters (mg/l)
| Category | CODCr | BOD5 | TSS | NH4-N | Ntot | Ptot |
|---|---|---|---|---|---|---|
| I | – | 70 | – | – | – | – |
| II | – | 50 | 50 | 30 | – | – |
| III | 150 | 40 | 40 | 20 | 40 | – |
| +P | 150 | 40 | 40 | 20 | 40 | 4 |
| +D | 150 | 40 | 40 | 20 | 40 | 4 |
Discharge into groundwater (mg/l)
| Category | CODCr | BOD5 | TSS | NH4-N | Ntot | Ptot |
|---|---|---|---|---|---|---|
| I | – | 40 | 40 | – | – | – |
| II | – | 40 | 40 | 20 | – | – |
| III | 125 | 40 | 40 | 15 | 25 | – |
| +P | 125 | 40 | 40 | 15 | 25 | 4 |
| +D | 125 | 40 | 40 | 15 | 25 | 4 |
For category +D, additional limits apply: E. coli 150 CFU/100 ml and enterococci 100 CFU/100 ml.
What the categories mean
- Category I: removal of organic pollution, the minimum requirements for most locations
- Category II: nitrification as well, where ammonium nitrogen needs to be limited
- Category III: both nitrification and denitrification, for example in protected water management areas
- Category +P: category III with additional phosphorus removal, for waters at risk of eutrophication
- Category +D: category III with disinfection, for example where treated water is reused
The district office specifies in your permit which category you need. More →
How sampling works
- Date agreed during normal operation, not straight after desludging or after you have been away for a longer time
- Sampling from the outlet or the inspection chamber into the laboratory’s sample bottles
- Chilled transport to the laboratory on the same day
- Test report from an accredited laboratory
- Entry in the operating log and an explanation of the results
We combine sampling with a service visit or a technical inspection, which saves you one call-out.
If a sample fails
The most common causes are too much sludge, a lack of air, incorrectly set recirculation, overloading or a chemical shock from cleaning products. We find the cause during a service visit, desludge and adjust the plant, and take a follow-up sample once it has become established again.
Frequently asked questions
Who can take the sample?
Under the government regulation, samples for compliance checks are taken by a certified inspection technician. The analysis is done by an accredited laboratory.
Do I have to send the results anywhere?
That depends on the conditions of your permit. Always record the results in the operating log, because the certified inspection technician checks them during the technical inspection.
I have an old permit that does not mention analyses. What should I do?
Owners of plants permitted under older regulations must apply to have their permit brought into line with current rules (zosúladenie povolenia) by 31 December 2032 at the latest. The new permit will also set out the analyses. We can help you with the documents.
Why choose Bednár Montáže
- Certified inspection technicianInspections are carried out by Daniel Bednár, who is on the Slovak University of Technology (STU) list of inspection technicians.
- Service after the warranty, tooWe look after your plant for years after start-up.
- Paperwork in orderA report and an operating log entry after every visit.
- Parts from our own online shopAir blowers, diaphragms and additives, average delivery 2.6 days.
- All of SlovakiaWestern Slovakia regularly, elsewhere by agreement. Advice also online via WhatsApp.
- Since 200026 years of experience with wastewater treatment plants.
Book a WWTP water analysis
We schedule it together with a service visit or an inspection. +421 905 229 394