Sludge test at home: a simple guide

In half an hour, a sludge test shows you how much sludge there is in your domestic wastewater treatment plant (WWTP) and how it settles. You need a measuring cylinder, gloves and a little care. The figure from the test only becomes meaningful, however, when you compare it with the value in the operating manual (prevádzkový poriadok) of your WWTP.

30 minutes
On this page

Quick guide

What a sludge test shows

In the activation zone, i.e. the aerated part of the plant, bacteria work in clumps called flocs. These flocs make up the activated sludge. When the sample is no longer stirred, the flocs sink to the bottom and water remains above them. The same happens in the separator, where the sludge separates from the treated water. The measuring cylinder is therefore a scaled-down model of the separator.

The technical term for the result is SV30, the sludge volume after 30 minutes of settling. You get two pieces of information: the figure tells you the amount of sludge, and its appearance tells you its condition. The test makes sense for activated sludge plants. For other types, follow the manufacturer’s instructions.

Hygiene and safety

Wastewater and sludge contain pathogens, even when the plant is working without any problems. Follow these rules during the test.

  • Wear rubber gloves, and safety glasses as well when pouring. Cover any cuts on your hands with a plaster.
  • Do not eat, drink, smoke or touch your face while you work.
  • When you have finished, wash your hands with soap, even if you wore gloves.
  • If the sample splashes into your eye, rinse it with clean water and see a doctor if you have any problems.
  • Keep children and animals away from the plant.
  • Use the equipment only for the test and do not store it near food.
  • Open the lid only briefly. Then close it and secure it so that nobody can fall into the tank.
  • Never enter the tank and do not lean over the opening. Gases that are dangerous to health and life can build up in closed tanks.
  • Do not touch electrical parts or the air blower with wet hands.

Step-by-step procedure

Have ready a 1-litre measuring cylinder, ideally a plastic one, a container on a long handle, a timer and something to write with.

  1. Check that the air blower is running and that the surface in the activation zone is bubbling. If aeration is paused at the moment, wait until the pause ends and let the contents mix for a few minutes.
  2. Take a sample from the activation zone below the surface and away from any foam, not from the separator or the outlet. If you do not know which part is the activation zone, look at the drawing in the manual.
  3. Pour the sample straight into the cylinder up to the 1,000 ml mark.
  4. Stand the cylinder on a level surface, away from vibration and out of direct sunlight.
  5. Start the timer and for the first five minutes watch how the flocs clump together and sink.
  6. After 30 minutes, read the boundary between the sludge and the water on the scale.
  7. Pour the sample and the water used to rinse the cylinder back into the activation zone, not onto the garden or down the sink. Close the lid and wash your hands.

How to read the figure

The cylinder’s scale is in millilitres. If the sludge boundary is at the 300 mark, the result is 300 ml/l, i.e. 30% of the volume. This figure is only an example of the calculation, not a recommended value.

Write the date, the figure and the appearance in the operating log (prevádzkový denník). A series of measurements tells you more than a single figure, so take the sample at a similar time of day and use the same cylinder.

A high figure does not automatically mean too much sludge. Bulking sludge, which compacts poorly, takes up a lot of space in the cylinder even if there is not too much of it in the plant. So always read the figure together with the appearance.

What the appearance of the sludge and the water above it tells you

The table is only a rough guide. Only a service technician can identify the cause reliably.

What you seeWhat it usually meansWhat to do
Brown sludge, a sharp boundary, clear water above itThe sludge is settling properlyRecord the result and change nothing
The sludge sinks slowly and stays looseFilamentous bacteria may be multiplying in the sludgeGet advice from your service technician
The sludge sinks quickly, small flocs float in the waterOld sludge or too much airAsk for advice on desludging and the air setting
Grey or milky water and little sludgeYoung sludge after start-up or desludging, or damage from chemicalsWait if the WWTP is new, otherwise find the cause
Black sludge and a smell of rotten eggsLack of oxygenCheck the air blower and the air supply
The sludge settles, then rises with bubblesDenitrification; the sludge may be staying too long in the separatorIf this happens within 30 minutes, call a service technician
Foam or a greasy film on the surfaceDetergents and fats; white foam can also mean young sludgeCheck what goes down the drain

With black sludge, start by checking the air blower. With cloudy water and foam, check what does not belong in a treatment plant. After chemical damage, ask your service technician about adding bacteria; our online shop ekotovar.sk (in Slovak) also sells them.

The desludging limit is in the operating manual

There is no universal value. Plants differ in the volume of both the activation zone and the separator, so the limits given in manuals and on the internet vary widely.

Important: Look for the desludging limit in the operating manual of your WWTP. The owner operates the plant in accordance with the decision of the district office (rozhodnutie okresného úradu), the operating manual and the manufacturer’s recommendations. If the value is missing there, ask the manufacturer or your service technician.

  • Result below the limit: record it and repeat the test at the next check.
  • Result close to the limit: plan desludging in advance. An interval of 6 to 12 months is commonly given, but the actual need depends on the load on the plant.
  • Result above the limit: book desludging. If sludge is also escaping into the effluent, do not put it off.

Desludging does not mean emptying the plant. Only the excess is pumped out, and part of the sludge with its bacteria must stay. The manufacturer’s instructions or the operating manual state how much sludge to leave. Sludge removal is carried out by an authorised contractor (oprávnená osoba), and a record of it belongs in the operating log. The sludge must not end up in surface water or groundwater. Repeat the test after desludging.

Frequently asked questions

How often should I do a sludge test?

The interval is given in the operating manual or the manufacturer’s instructions. If it is not, do the test at each regular check and whenever the appearance of the effluent changes or an odour appears.

Can I use a preserving jar instead of a measuring cylinder?

As a rough guide, yes, if it has straight sides. Divide the height of the sludge by the height of the whole sample and multiply by 100. To compare the result with the limit in the operating manual, use a measuring cylinder.

Does a sludge test replace a water analysis or a technical inspection?

No. The test is your own rough check. An analysis of a sample of the discharged water and the technical inspection (technická revízia) are separate obligations.

Sources: Act No. 364/2004 Coll., Government Regulation No. 269/2010 Coll.

Why choose Bednár Montáže

  • Since 200026 years of experience with wastewater treatment plants.
  • Everything from one companySales, design, permit, guides, service, inspection and parts.
  • Certified inspection technicianInspections are carried out by Daniel Bednár, who is on the Slovak University of Technology (STU) list of inspection technicians.
  • All of SlovakiaWestern Slovakia regularly, elsewhere by agreement. Advice also online via WhatsApp.

Not sure what your test result means?

Send us the result and a photo of the cylinder by email or via WhatsApp. +421 905 229 394