How much it costs to run a treatment plant each year
The running costs of a domestic wastewater treatment plant (WWTP) cannot be expressed as one figure that applies to everyone.
7 min readIn half an hour, a sludge test shows you how much sludge there is in your domestic wastewater treatment plant (WWTP) and how it settles. You need a measuring cylinder, gloves and a little care. The figure from the test only becomes meaningful, however, when you compare it with the value in the operating manual (prevádzkový poriadok) of your WWTP.
Put on gloves. Check that the air blower is running and that the surface in the aerated zone is bubbling.
Take a sample from just below the surface in the aerated zone and pour it into a clear measuring cylinder.
Place the cylinder on a level surface where it will not be shaken. The sludge flocs will start to sink to the bottom.
After 30 minutes, read off the boundary between the sludge and the water and write the result in your operating log.
Compare the value with the operating manual. Pour the sample back into the aerated zone and wash your hands.
In the activation zone, i.e. the aerated part of the plant, bacteria work in clumps called flocs. These flocs make up the activated sludge. When the sample is no longer stirred, the flocs sink to the bottom and water remains above them. The same happens in the separator, where the sludge separates from the treated water. The measuring cylinder is therefore a scaled-down model of the separator.
The technical term for the result is SV30, the sludge volume after 30 minutes of settling. You get two pieces of information: the figure tells you the amount of sludge, and its appearance tells you its condition. The test makes sense for activated sludge plants. For other types, follow the manufacturer’s instructions.
Wastewater and sludge contain pathogens, even when the plant is working without any problems. Follow these rules during the test.
Have ready a 1-litre measuring cylinder, ideally a plastic one, a container on a long handle, a timer and something to write with.
The cylinder’s scale is in millilitres. If the sludge boundary is at the 300 mark, the result is 300 ml/l, i.e. 30% of the volume. This figure is only an example of the calculation, not a recommended value.
Write the date, the figure and the appearance in the operating log (prevádzkový denník). A series of measurements tells you more than a single figure, so take the sample at a similar time of day and use the same cylinder.
A high figure does not automatically mean too much sludge. Bulking sludge, which compacts poorly, takes up a lot of space in the cylinder even if there is not too much of it in the plant. So always read the figure together with the appearance.
The table is only a rough guide. Only a service technician can identify the cause reliably.
| What you see | What it usually means | What to do |
|---|---|---|
| Brown sludge, a sharp boundary, clear water above it | The sludge is settling properly | Record the result and change nothing |
| The sludge sinks slowly and stays loose | Filamentous bacteria may be multiplying in the sludge | Get advice from your service technician |
| The sludge sinks quickly, small flocs float in the water | Old sludge or too much air | Ask for advice on desludging and the air setting |
| Grey or milky water and little sludge | Young sludge after start-up or desludging, or damage from chemicals | Wait if the WWTP is new, otherwise find the cause |
| Black sludge and a smell of rotten eggs | Lack of oxygen | Check the air blower and the air supply |
| The sludge settles, then rises with bubbles | Denitrification; the sludge may be staying too long in the separator | If this happens within 30 minutes, call a service technician |
| Foam or a greasy film on the surface | Detergents and fats; white foam can also mean young sludge | Check what goes down the drain |
With black sludge, start by checking the air blower. With cloudy water and foam, check what does not belong in a treatment plant. After chemical damage, ask your service technician about adding bacteria; our online shop ekotovar.sk (in Slovak) also sells them.
There is no universal value. Plants differ in the volume of both the activation zone and the separator, so the limits given in manuals and on the internet vary widely.
Important: Look for the desludging limit in the operating manual of your WWTP. The owner operates the plant in accordance with the decision of the district office (rozhodnutie okresného úradu), the operating manual and the manufacturer’s recommendations. If the value is missing there, ask the manufacturer or your service technician.
Desludging does not mean emptying the plant. Only the excess is pumped out, and part of the sludge with its bacteria must stay. The manufacturer’s instructions or the operating manual state how much sludge to leave. Sludge removal is carried out by an authorised contractor (oprávnená osoba), and a record of it belongs in the operating log. The sludge must not end up in surface water or groundwater. Repeat the test after desludging.
The interval is given in the operating manual or the manufacturer’s instructions. If it is not, do the test at each regular check and whenever the appearance of the effluent changes or an odour appears.
As a rough guide, yes, if it has straight sides. Divide the height of the sludge by the height of the whole sample and multiply by 100. To compare the result with the limit in the operating manual, use a measuring cylinder.
No. The test is your own rough check. An analysis of a sample of the discharged water and the technical inspection (technická revízia) are separate obligations.
Sources: Act No. 364/2004 Coll., Government Regulation No. 269/2010 Coll.
Send us the result and a photo of the cylinder by email or via WhatsApp. +421 905 229 394
Strictly necessary cookies keep the website working. With your consent, we also use analytics and marketing cookies (Google, Meta, LinkedIn, Pinterest) to measure traffic and for advertising. You can change your consent at any time using the Cookie settings link in the footer. More about cookies