Treatment plant bacteria: when they help and when they do not

In normal operation, a domestic wastewater treatment plant (WWTP) maintains its own culture of bacteria and does not need regular doses from a sachet. An additive can help at start-up, after a chemical shock or after a long absence. It will not, however, fix a faulty air blower or too much sludge.

Bacteria treat the water for you
On this page

Why a plant in normal operation does not need an additive

Bacteria enter the plant every day with the wastewater. In the activation zone they feed on the pollution, multiply and form activated sludge. Once the sludge has settled, it is pumped back, so the bacteria do not end up in the effluent.

The plant needs four things: air, a regular inflow, a reasonable amount of sludge and water without aggressive chemicals. If it has these, there are enough bacteria in it. Compared with them, a single dose of an additive is a small addition, as Washington State University also points out in its guidance for septic tank owners.

In a 2024 fact sheet, the US Environmental Protection Agency (EPA) does not recommend bacterial additives for septic tanks. It states that the necessary microorganisms are present in the tank without them and that only limited independent research supports the manufacturers’ claims. A septic tank and an activated sludge WWTP are not the same thing, but the basic logic is the same.

When an additive can help

In three situations there really are too few bacteria in the plant, and an additive can shorten the wait. There are few independent comparisons carried out directly on domestic treatment plants, however, so treat it as an aid, not a guarantee.

When a new plant is started up

A new WWTP is filled with water and has no activated sludge in it yet. The bacterial culture grows slowly, so the plant usually treats the water fully only after several weeks, and later in cold weather. The plant will become established without help. Seeding it with sludge from a working plant or with a bacterial additive can shorten this time.

If the effluent is slightly cloudy at first or some foam appears, another dose is not needed. You will find the procedure on our page WWTP start-up and seeding.

After a chemical shock

A chemical shock happens when too many aggressive chemicals get into a small tank at once, typically chlorine disinfectant or drain cleaner. In a large sewer network such a substance is diluted; in a domestic treatment plant it is not. Laboratory tests at the Slovak University of Technology in Bratislava (Bodík et al., 2005) showed that with one of the chlorine products, 0.1 to 0.3 litres in a plant with a volume of 1 m³ can suppress the basic treatment processes by 30 to 90%. In these tests, products without chlorine had a much weaker effect.

The sludge can recover on its own, but it takes longer. If you want to speed up the recovery, keep to the right order. The substance that suppressed the original sludge will also hit any bacteria added straight after it. The Washington State University guidance points this out too.

  1. Do not pour any more chemicals down the drain, and leave the air blower running.
  2. Wait until the substance has been diluted by the inflow. How long this takes depends on the type and amount of the substance. After a larger spill, call a service technician.
  3. Only then add the additive according to the manufacturer’s instructions.
  4. Record it in the operating log (prevádzkový denník) as an exceptional event.

To prevent it, see our overview of what not to put in a WWTP.

After a long absence

An ordinary holiday does not call for an additive. A cottage or a house left empty for several months is a different matter. Without inflow, the bacteria have nothing to consume and the amount of sludge gradually falls. When you return, the plant has to get going again, and an additive can shorten this time.

Switch the air blower off during your absence only if the operating manual (prevádzkový poriadok) of your WWTP allows it. When you return, check that it is running, and increase the load on the plant gradually, not with several loads of laundry in a row.

When an additive will not help

If the problem lies in the equipment or the amount of sludge, an additive only delays the real fix.

ProblemWhy an additive will not helpWhat to do
The air blower is not running or blows weaklyThe bacteria in the activation zone need oxygen. Without it, even the bacteria from the additive will not work.Check the circuit breaker and the filter, have the blower repaired or replaced
Too much sludge, sludge on the surface or in the effluentSludge builds up precisely because the bacteria grow. More bacteria will not take it away.Book desludging by an authorised contractor (oprávnená osoba)
Rainwater in the drains, a lot of laundry at onceThe problem is excessive inflow, which washes out the sludge, not a lack of bacteria.Disconnect the rainwater, do not run several washes in a row
Poorly adjusted recirculation, blocked airlift pumpsThe sludge does not return where it should.Have the plant checked and adjusted
Regular use of chlorine productsEvery round of cleaning suppresses the bacteria again.Switch to cleaning products without chlorine

Be cautious about the promise of “less sludge”. The EPA admits that some additives reduce the sludge layer in a septic tank. Washington State University, on the other hand, cites a study of 48 septic tanks in which the sludge level was the same with and without an additive.

An additive does not replace the operator’s obligations. Under Government Regulation No. 269/2010 Coll. (Section 5a), regular sludge removal, keeping records of it and checking that the plant works properly are part of operating a WWTP. The technical inspection (technická revízia) is required by the Water Act (Act No. 364/2004 Coll.), Section 53(2).

How to use an additive so that it makes sense

  1. Check the cause. The air blower must be running, the air must bubble through evenly and there must not be too much sludge. A sludge test will help.
  2. Choose the right additive. It should be intended for domestic treatment plants.
  3. Dose according to the instructions. A bigger dose will not remove the cause. Do not lean over the open tank when dosing, because the gases from it are dangerous.
  4. Leave out chlorine. While the plant is recovering, do not let any chlorine products or large amounts of water into it at once.
  5. Watch the result. If the effluent has not improved even after several weeks, the cause probably lies elsewhere and the plant needs servicing.

Our online shop ekotovar.sk (in Slovak) has a separate Baktérie do ČOV category (WWTP bacteria). We sell these additives, but we recommend buying them only in the situations described above.

Frequently asked questions

Do I have to add bacteria to my treatment plant regularly?

No. If the plant has air and a reasonable amount of sludge and does not receive aggressive chemicals, it maintains its bacteria by itself.

Will bacteria get rid of the smell from the plant?

As a rule, no. An odour is usually caused by a lack of air or too much sludge, so check the air blower and the amount of sludge.

Should I add bacteria after the plant has been desludged?

Usually not. Part of the activated sludge stays in the tank, and the plant recovers from it within a few days. Checking the settings helps. An additive may make sense if the tank was emptied completely.

Do I need to add bacteria when someone in the household is taking antibiotics?

A normal course of treatment is usually no reason to. In a laboratory test at the Slovak University of Technology, one antibiotic slightly reduced the activity of the sludge, and only at a dose of ten tablets. It was just one medicine and a short test, so treat the result as a rough guide. Unused medicines do not belong in the toilet or down the drain.

Sources: Government Regulation No. 269/2010 Coll., Act No. 364/2004 Coll., U.S. EPA: Septic Tank Additives Fact Sheet

Why choose Bednár Montáže

  • Since 200026 years of experience with wastewater treatment plants.
  • Everything from one companySales, design, permit, guides, service, inspection and parts.
  • Certified inspection technicianInspections are carried out by Daniel Bednár, who is on the Slovak University of Technology (STU) list of inspection technicians.
  • All of SlovakiaWestern Slovakia regularly, elsewhere by agreement. Advice also online via WhatsApp.

Not sure what your plant is missing?

Call us and we will help you find the cause before you buy an additive you may not need. +421 905 229 394